Chapter 3 Operation Installation and Operation Manual
3-2 Default Settings Egate-100 Ver. 4.0
Table
3-1. Egate-100 LED Indicators
Name Color Function
POWER Green/Red Green: Power supply performing properly
Red: Power supply error or disconnected
RDY Green On: Self test completed successfully
Blinking: Self test failed
ALM Red On: Interface or system alarm activated
Off: No Alarm
LINK (GbE) Green On: Ethernet connection is up
Off: Ethernet connection is down
ACT (GbE) Yellow Blinking: Ethernet frame was received or sent
within the last second
SYNC 1 Green STM-1/OC-3 version:
On: STM-1 port is synchronized
Off: LOS, LOF
DS-3 version:
On: T3 port is synchronized
Off: LOS
SYNC 2
3.3 Default Settings
Table
3-2
lists the default settings of the Egate-100 configuration parameters.
Table
3-2. Default Settings
Component Parameter Default Value
System Device Name EGATE-100
Location The Location of this Device
Contact Person Name of Contact Person
IP address 0.0.0.0
IP mask 0.0.0.0
Default gateway 0.0.0.0
Read community Public
Write community (null)
Trap community (null)
Host Tagging Untagged
Host VLAN ID 1
Host Priority Tag 0