Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Configuring Egate-100 for Operation 4-55
Table
4-26. Gigabit Ethernet Port Parameters
Parameter Description Possible Values
Port Choose the desired Ethernet port
Default: GbE-1
GbE-1
GbE-2
ETH MNG
Port Name Choose the desired Ethernet port
name
Port GbE-1
Port GbE-2
Port ETH-MNG
Administrative
Status
Defines if port is available for
operation
Default: Down
Up
Down
Name String identifying the port String of characters
Auto Negotiation Enabling autonegotiation allows for
automatic determination of the speed
and duplex mode.
For 1000BaseT, autonegotiation is
mandatory and enabled by default.
Autonegotiation is also mandatory for
Gigabit Ethernet redundancy
Default: Disabled
Enabled
Disabled
Speed & Duplex Appears if Auto Negotiation is
disabled:
The speed can be 10/100BaseT at full
duplex or half duplex.
For Gigabit Ethernet redundancy, both
links must be set to the same speed
and to Full Duplex.
10 Mbps Half Duplex
10 Mbps Full Duplex
100 Mbps Half Duplex
100 Mbps Full Duplex
Ethernet Max
Capability
Advertised
Appears if Auto Negotiation is enabled
and the Port is not ETH MNG:
Define the maximum speed and duplex
mode. The system will not exceed the
speed you specified even if the ports
were able to negotiate a faster speed.
10 Mbps Half Duplex
10 Mbps Full Duplex
100 Mbps Half Duplex
100 Mbps Full Duplex
1000 Mbps Full Duplex
Alarms Mask Gigabit Ethernet alarms
Default: Unmasked
Masked
Unmasked (default)
Configuring Logical Layer Parameters
Logical port configuration includes the definition of the protocol for each physical
E1/T1 port. After a logical port is defined, it is bound to a bridge port, and bridge
port properties are configured.
Logical ports can be used to define one or more of the following:
Ethernet over HDLC over E1/T1