Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
Egate-100 Ver. 4.0 Detecting Problems 5-21
Table
5-16. Ethernet Alarms List
Code Event Description
200 Link integrity fail The FE port integrity failed
Table
5-17. Logical Ports Alarms List
Code Event Description
221 No match to bundle The logical port cannot be added to the
pseudowire (bundle)
222 LCP Fail LCP down for PPPoHDLC ports
223 BCP Fail BCP down for MLPPP ports
224 GFP Out Sync GFP signals are out of sync.
225 Loop Detected HW Hardware loop detected on the physical layer.
Frames are returning due to an error along the
path or because a loop was defined on the
relevant physical port.
Table
5-18. Bridge Ports Alarms List
Code Event Description
241 Remote link fail OAM/EFM detected that the remote link failed.
242 Remote critical event OAM/EFM detected a critical event.
243 Remote dying gasp OAM/EFM alarm indicates that the power supply
is failing.
244 Loop detected Loop detected on the bridge port.
Traps
Refer to
Table
5-19
for the list of traps sent by Egate-100.
Table
5-19. Trap List
Trap Description OID
coldStart The unit has been restarted 1.3.6.1.6.3.1.1.5.1
authenticationFailure User authentication has failed 1.3.6.1.6.3.1.1.5.5
linkDown Interface has been disconnected 1.3.6.1.6.3.1.1.5.3
linkUp Interface has been connected 1.3.6.1.6.3.1.1.5.4
ApsEventSwitchover SDH/SONET APS switchover has
occurred
1.3.6.1.2.1.10.49.2.0.1
successfulLogin Successful login occurred 1.3.6.1.4.1.164.6.1.0.24
failedLogin Failed login occurred 1.3.6.1.4.1.164.6.1.0.25