Chapter 4 Configuration Installation and Operation Manual
4-34 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
Parameter Description Possible Values
Traffic Class 2 Total Total burst supported for all bridge port
priority queues of traffic class 2
Default: 600
1–2500
Traffic Class 3 Total Total burst supported for all bridge port
priority queues of traffic class 3 (lowest
priority)
Default: 2500
1–2500
GbE Max Buffers Maximum burst supported for Gigabit
Ethernet port
Default: 50
1–2500
ETH 1Max Buffers Maximum burst supported for Fast
Ethernet port
Default: 100
1–2500
HOST Max Buffers Maximum burst supported for Host port
Default: 100
1–2500
Set to Default Restores the default buffer mangement
configuration.
Configuring the Syslog Parameters
Syslog enables you to forward log messages via UDP over the network to a
receiving device, referred to as server from this point on.
³ To configure the Syslog parameters:
1. From the System menu (Configuration > System), select Syslog.
The Syslog menu is displayed (see
Figure
4-34
).
2. Configure the Syslog parameters according to
Table
4-12
.
3. Select Save.
Egate-100
Configuration> System> Syslog
1. Device Logging Status > (Enabled)
2. Device UDP Port [1-65535] ... (514)
3. Facility > (Local 1)
4. Severity Level > (Minor)
5. Server Parameters >
>
S-Save
ESC-Previous menu; !-Main menu; &-Exit
Figure
4-34. Syslog Menu