Chapter 6 Software Upgrade Installation and Operation Manual
Downloading an Application Using TFTP
The TFTP server must be connected to Egate-100 via the Ethernet-1 port.
³ To download an application file using TFTP:
1. Select TFTP Protocol in the Application File Not Found menu.
The TFTP Parameters Setting menu appears.
BOOT WP 787-Rev-B1 - TFTP PARAMETERS SETTING
FILE NAME: e-gate.img
HOST IP: 172.17.140.123
HOST MASK: 255.255.255.0
DEFAULT GATEWAY: 172.17.140.1
TFTP IP SERVER: 192.168.238.173
Press S to start transferring the file (N to cancel).
Figure
6-9. TFTP Parameters Setting Menu
2. Enter the file name, host IP, host mask, and default gateway information.
3. Type s.
The downloading begins. Once the downloading is completed, Egate-100
is reset automatically.
Additional Boot Menu Commands
The File Menu is an option that allows the user to perform basic file transfer
operations. These operations are all optional.
³ To access the File Menu:
Select File Utility in the Boot Option menu.
The File Menu appears.
RAD BOOT
FILE MENU
0. Reset the System
1. File swap: Operating backup
2. Delete Operating file (existing backup will be saved as
operating)
3. Delete Configuration file
4. Delete ALL file system (Software and Configuration files)
Select operating mode:
Figure
6-10. File Menu
From the File menu, you can:
Exchange the operating and backup files
Delete the operating file. The backup file becomes the operating file
6-8 Upgrading Egate-100 Software via the Boot Menu Egate-100 Ver. 4.0