RAD Data comm 100 Spezifikationen Seite 283

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 318
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 282
Installation and Operation Manual Chapter 7 Application Tutorial
Egate-100 Ver. 4.0 WiMAX Backhauling Opposite RICi-4T1 7-39
For more information on displaying and understanding the bridge statistics,
see Chapter 5,
Viewing Bridge Statistics
.
7.3 WiMAX Backhauling Opposite RICi-4T1
Figure
7-52
illustrates a typical application where Egate-100 provides WiMAX
backhauling over SDH/SONET, operating opposite multiple RICi-4T1s. Egate-100 is
managed via the Fast Ethernet management port. Different user VLANs are used
for each customer and a separate VLAN is used for secured management traffic.
Figure
7-52. Egate-100 Application with WiMAX backhauling opposite RICi-4T1,
Management via Fast Ethernet Port
The following is required to set up this application:
1000 BaseT/BaseSx connection to the packet-switched network
T3 links to the SDH/SONET network where RICi-4T1s are installed
Fast Ethernet management port
Network management station for management.
Equipment List
The following is a list of equipment needed to set up this application:
The following equipment is needed to set up this application:
Egate-100
Seitenansicht 282
1 2 ... 278 279 280 281 282 283 284 285 286 287 288 ... 317 318

Kommentare zu diesen Handbüchern

Keine Kommentare