Chapter 4 Configuration Installation and Operation Manual
4-42 Configuring Egate-100 for Operation Egate-100 Ver. 4.0
³ To configure SDH/SONET SOH:
1. Navigate to Main Menu > Configuration > Physical Layer >SDH/SONET > SOH.
The SOH menu appears as illustrated in
Figure
4-41
.
Egate-100
Main Menu> Configuration> Physical Layer> SDH/SONET> SOH
1. Port Number >...(1)
2. Path Trace (01)
3. RS-TIM > (Disable)
4. Path Trace Padding (Spaces)
5. Alarms > (Unmasked)
6. Event Threshold []>
Please select item <1 to 6>
F - Forward Port; B - Backward Port; S - Save
ESC-prev.menu; !-main menu; &-exit
Figure
4-41. SDH/SONET SOH Menu
2. Configure SOH parameters according to
Table
4-18
.
Table
4-18. SDH/SONET SOH Parameters
Parameter Description Possible Values
Port Number Parameters can be specified for an
individual or range of ports.
1–2
Path Trace Defines the J0 transmit path trace
string
Default: 01
01 (SDH)
J0 – Tx Path (SONET)
RS-TIM Defines whether to check the
received J0 path trace
Default: Disable
Enable
Disable
Path Trace Padding Defines the type of path trace
padding used to fill the path trace
length
Default: Spaces
Spaces
Null
Alarms Section and Line Overhead alarms,
per port.
For each port, or range of ports,
select the port number and specify
whether to mask or unmask alarms.
Default: Unmasked
Masked
Unmasked
³ To configure SOH event threshold:
1. Navigate to Main Menu > Configuration > Physical Layer >SDH/SONET > SOH
and select Event Threshold.
The SOH Event Threshold menu appears as illustrated in
Figure
4-42.
Kommentare zu diesen Handbüchern