Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Configuring Egate-100 for Operation 4-39
Egate-100
Main Menu> Configuration> Physical Layer> SDH/SONET> E1/T1
1. Port Number [1-63] ... (5-12)
2. Administrative Status > (Up)
3. Frame Type > (Unframed)
4. Idle Code [0-ff] ... (0)
5. Alarms > (Unmasked)
6. Event Threshold []>
Please select item <1 to 6>
F - Forward Port; B - Backward Port; S - Save
ESC-prev.menu; !-main menu; &-exit
Figure
4-39. SDH/SONET STM-1 E1/T1 Menu
2. Select an individual E1/T1 Port Number or a range of ports. You can map up
to 63 E1s or 84 T1s (in case of E1 over VC12 or T1 over VT1.5).
To move to the next port, type F.
To move to the previous port, type B.
3. Configure parameters for E1 according to
Table
4-15
or T1 according to
Table
4-16
respectively.
Table
4-15. SDH/SONET E1/T1 Parameters (E1)
Parameter Remarks Possible Values
Port Number Parameters can be specified for an
individual or range of ports.
1-63
Administrative
Status
User-controlled activation of the
port.
Default: Up
Up
Down
E1 Frame Type Specifies the framing mode,
including for Ethernet o fractional
E1, if E1 is defined as framed.
Default: Unframed
Unframed
Framed-CRC4
Framed-NoCRC4
E1 Idle Code E1 Idle code parameter. For E1
Framed only
Default: 01
0-FF
E1 Alarms Specifies whether to use masking or
not.
Default: Unmasked
Masked
Unmasked
Table
4-16. SDH/SONET E1/T1 Parameters (T1)
Parameter Remarks Possible Values
Port Number Parameters can be specified for an
individual or range of ports.
1-84