Appendix B LED Indicators User's Manual
B-4 LRS-24 LED Indicators LRS-24 RADview/TDM
Name Color LED On LED Off Blinking
TEST Red Test is running Not On –
ERR Red Failure occurred – –
ASMi-50C Card LED Indicators
Table B-7. ASMi-50C LEDs
Name Color LED On LED Off Blinking
POWER Green Always – –
TD Yellow – Not blinking Data passing through
RD Yellow – Not blinking Data passing through
RTS Yellow RTS status = On – –
DCD Yellow DCD status = On – –
LINE LOS Red Loss of synchronization on line interface – –
LINE QLTY Green
Red
Line quality = Good
Line quality = Bad
– Line quality = Mid
TEST Red Test is running Not on –
ERR Red Failure occurred – –
ASMi-50CD Card LED Indicators
Table B-8. ASMi-50CD LEDs
Name Color LED On LED Off Blinking
POWER Green Always – –
TD 1 – 2 Yellow – Not blinking Data passing through
RD 1 – 2 Yellow – Not blinking Data passing through
RTS 1 – 2 Yellow RTS status = On – –
DCD 1 – 2
Yellow DCD status = On – –
SYNC 1 – 2
Red
Green
Loss of synchronization on line
interface
Good synchronization on line interface
– –
TEST 1 – 2 Red Test is running Not On –
ERR 1 – 2 Red Failure occurred – –
ASMi-51CQ/CQ-E1 Card LED Indicators
Kommentare zu diesen Handbüchern