Chapter 5 Performance Management User's Manual
5-12 Monitoring Modem Performance LRS-24 RADview/TDM
Table 5-4. Line (HDSL) Current Data Parameters
Parameter Possible Values / Remarks
Time Elapsed (sec) Amount of time that has passed since the beginning of the current 15-minute
interval
0..899
Read-only
Errored Seconds Contain one or more of the following events:
• CRC error event, SEF (OOF) event, or AIS
• OOF defect is the occurrence of framing bits error
If SES is effective concurrently, ES runs for 10 seconds and stops.
Read-only
Severly Errored Seconds Contain 320 or more CRC error events, one or more SEF (OOF), or AIS. OOF defect
is the occurrence of framing bits error.
Read-only
Background Block Errors Errored blocks that do not occur in severely errored blocks.
ASMi-51/CD/CQ only
Read-only
Unavailable Seconds Number of seconds in the current interval in which a failed signal state exists.
Read-only
Noise Margin (db) Noise Margin
ASMi-51/CD/CQ only
Read-only
Attenuation (db) Attenuation
ASMi-51/CD/CQ only
Read-only
Current Data Graph
To view the Line (HDSL) Current Data graph:
• In the Zoom view, select the modem (near end or far end), right click and
select Statistics > Line (HDSL) > Current Data > Graph.
Kommentare zu diesen Handbüchern