User's Manual Chapter 5 Performance Management
LRS-24 RADview/TDM Monitoring Modem Performance 5-21
Parameters Possible Values / Remarks
SHDSL Mode Available for ASMi-52 family only.
STU-C, STU-R (for Modem Port Line Clock Source)
Read-only
Inv No. 1-96
If the number of intervals=0, then the Interval Table has one empty row
Read-only
From (hh:mm)
Start time of the interval
In hours (hh) and minutes(mm).
Read-only
To (hh:mm) End time of the interval
In hours (hh) and minutes(mm).
Read-only
ES Errored Seconds
A second containing one or more of the following events:
CRC error event, SEF (OOF) event, or AIS
OOF defect is the occurrence of framing bits error
If SES is also effective at the same time, ES will run for 10 seconds and stop
Read-only
SES Severely Errored Seconds
320 or more CRC error events, one or more SEF (OOF), or AIS. OOF defect is the occurrence
of framing bits error
Read-only
CRC
Anomalies
(ASMi 52/CD/CQ only)
Read-only
LOSWS Loss of Sync Word Seconds.
(ASMi 52/CD/CQ only)
Read-only
UAS Unavailable Seconds
Number of seconds in the current interval in which a failed signal state exists
Read-only
15-Minute Intervals Data Graph
To view the 15-Minute intervals data graph:
• In the Zoom view, select the modem (near end or far end), right click and
select Statistics > Line A or B (SHDSL) > 15 min Intervals Data > Graph.
Kommentare zu diesen Handbüchern