Chapter 5 Performance Management User's Manual
5-32 Monitoring Modem Performance LRS-24 RADview/TDM
Parameters Possible Values / Remarks
Mode Modem mode
Master-Permanent, Master-Temporary, Slave-Permanent, Slave-Temporary
Read-only
SHDSL Mode Available for ASMi52 family only.
STU-C, STU-R (for Modem Port Line Clock Source)
Read-only
No. of Intervals 1-96
If the number of intervals=0, then the Interval Table has one empty row
Read-only
Inv No. 1-96
If the number of intervals=0, then the Interval Table has one empty row
Read-only
From (hh:mm) Start time of the interval
In hours (hh) and minutes(mm).
Read-only
To (hh:mm) End time of the interval
In hours (hh) and minutes(mm).
Read-only
ES Errored Seconds
A second containing one or more of the following events:
CRC error event, SEF (OOF) event, or AIS
OOF defect is the occurrence of framing bits error
If SES is also effective at the same time, ES will run for 10 seconds and stop
Read-only
SES Severely Errored Seconds
320 or more CRC error events, one or more SEF (OOF), or AIS. OOF defect is the
occurrence of framing bits error
Read-only
UAS Unavailable Seconds
Number of seconds in the current interval in which a failed signal state exists
Read-only
CSS Number of Controlled Slip Seconds
Read-only
BES Number of Bursty Errored Seconds
Read-only
LOFC Loss of Frame Counter
Read-only
DM Degraded Minutes
ASMi-52/CD/CQ only
Read-only