Chapter 2 Agent Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
Table 2-43. Port Active Alarm List Parameters
Parameter Possible Values / Remarks
Code Code number of the alarm
Description Brief description of the alarm
Severity Alarm severity
Status Type of alarm
Off – No alarms or events in port.
Event – At least one alarm event (including state on, off events) since the last
Alarms>Clear operation
Major – At least one active major alarm since the last Alarms>Clear operation
Minor – At least one active minor alarm since the last Alarms>Clear operation
Mask/Invert Indicaties whether the alarm is masked or inverted
Counter Number of times that this alarm occurred since either Megaplex startup or the last time
the alarm list was cleared
[Save File…] Saves alarms list in a file. In the Save dialog box, select a path, type a filename and Click
<OK>. RADview adds the extension *.alr to the filename.
[Clear] Clears all active alarms. Confirmation is not required.
Clearing Port Alarms
The Alarms>Clear command clears active port alarms from the Port Active Alarms
list:
To clear active port alarms from the Port Active Alarms List:
From the Fault menu, select Alarms and Clear.
No user confirmation is requested.