RADview-PC/TDM Megaplex-2100/2104 User’s Manual Chapter 2 Agent Configuration Mode
Displaying All Active Alarms
To display a list of all Megaplex active alarms:
From the Fault menu, select Alarms followed by Display and All… or click
the Alarms>Display button .
The Mux Active Alarm List appears. The order of alarms in the table can be
sorted by clicking on the column headers with an asterix “*”.
Figure 2-28. Mux All Active Alarm List
Table 2-14. Mux All Active Alarm Parameters
Parameter Possible Values / Remarks
No. Alarm No.
Code Code number of the alarm
Slot IO slot where alarm occurred
Port Port where alarm occured
Description Brief description of the alarm
Severity Indication of the effect level of the alarm:
Event, Warning, Minor, Major, Critical
State Type of alarm:
Off - No alarms or events in port
Event - At least one alarm event (including state on, off events) since the last
Alarms>Clear operation
Major - At least one active major alarm since the last Alarms>Clear operation
Minor - At least one active minor alarm since the last Alarms>Clear operation
Megaplex Level Fault Operations 2-27