RAD Data comm FLM-1 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Nein RAD Data comm FLM-1 herunter. RAD Data comm FLM-1 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
FLM-1
6/12 Port Fiber-Optic Multiplexer
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications. No part of this
publication may be reproduced in any form whatsoever without prior written approval by RAD Data
Communications.
No representation or warranties for fitness for any purpose other than what is specifically mentioned in
this manual is made either by RAD Data Communications or its agents.
For further information contact RAD Data Communications at the address below or contact your local
distributor.
International Headquarters
RAD Data Communications Ltd.
24 Raoul Wallenberg St.
Tel Aviv 69719 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
U.S. Headquarters
RAD Data Communications Inc.
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100
Toll free: 1-800-444-7234
Fax: (201) 529-5777
© 2001 RAD Data Communications Publication No. 303-200-02/01
Seitenansicht 0
1 2 3 4 5 6 ... 33 34

Inhaltsverzeichnis

Seite 1

FLM-16/12 Port Fiber-Optic MultiplexerInstallation and Operation ManualNoticeThis manual contains information that is proprietary to RAD Data Communic

Seite 2 - Regulatory Information

Chapter 1 - Introduction FLM-1 Installation & Operation Manual1-2 Overview 16/01/01 11:12 AM Figure 1-1 Typical Point-to-Point ApplicationRing A

Seite 3 - Telecommunication Safety

FLM-1 Installation & Operation Manual Chapter 1 - Introduction16/01/01 11:12 AM Physical Description 1-3Table 1-1 shows distortion per node and

Seite 4 - Declaration of Conformity

Chapter 1 - Introduction FLM-1 Installation & Operation Manual1-4 Functional Description 16/01/01 11:12 AMFront PanelThe front panel provides con

Seite 5 - Contents

FLM-1 Installation & Operation Manual Chapter 1 - Introduction16/01/01 11:12 AM Technical Specifications 1-5Note1. The distortion refers to the

Seite 6

Chapter 1 - Introduction FLM-1 Installation & Operation Manual1-6 Technical Specifications 16/01/01 11:12 AMOptical InterfaceTransmission lineDou

Seite 7 - List of Tables

FLM-1 Installation & Operation Manual Chapter 1 - Introduction16/01/01 11:12 AM Technical Specifications 1-7Power100/115/230 VAC (± 10%), 50-60

Seite 8

Chapter 1 - Introduction FLM-1 Installation & Operation Manual1-8 Technical Specifications 16/01/01 11:12 AM

Seite 9 - Introduction

16/01/01 11:12 AM Package Contents 2-1Chapter 2Installation and Setup2.1 IntroductionThis chapter provides instructions for mechanical and electrica

Seite 10

Chapter 2 - Installation and Setup FLM-1 Installation & Operation Manual2-2 Installation and Setup 16/01/01 11:12 AM2.4 Installation and SetupTh

Seite 11 - Physical Description

FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup16/01/01 11:12 AM Installation and Setup 2-3SELECT6 OR 12CHANNELS1232J16G

Seite 12 - Functional Description

WarrantyThis RAD product is warranted against defects in material and workmanship for a period of one yearfrom date of shipment. During the warranty p

Seite 13 - Main Channel

Chapter 2 - Installation and Setup FLM-1 Installation & Operation Manual2-4 Installation and Setup 16/01/01 11:12 AM11 5 VA C0.2A T 250VMAIN CHANN

Seite 14 - Indicators

FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup16/01/01 11:12 AM Installation and Setup 2-5Protective GroundTransmitted

Seite 15 - Environment

Chapter 2 - Installation and Setup FLM-1 Installation & Operation Manual2-6 Installation and Setup 16/01/01 11:12 AMRJ-45 ConnectorsTwelve RJ-45 m

Seite 16

FLM-1 Installation & Operation Manual Chapter 2 - Installation and Setup16/01/01 11:12 AM Installation and Setup 2-7Connecting the Main Channel4-

Seite 17 - Installation and Setup

Chapter 2 - Installation and Setup FLM-1 Installation & Operation Manual2-8 Installation and Setup 16/01/01 11:12 AMWarningBefore connecting power

Seite 18 - 2.4 Installation and Setup

09/01/01 4:29 PM Front Panel Indicators and Switches 3-1Chapter 3Operating Instructions3.1 GeneralThis chapter covers:• A list of controls and indic

Seite 19 - Interfaces

Chapter 3 - Operation FLM-1 Installation & Operation Manual3-2 Operating Instructions 09/01/01 4:29 PMTable 3-1 lists the functions of the FLM-1 i

Seite 20 - Connecting the Subchannels

09/01/01 4:29 PM Diagnostics Tests 4-1Chapter 4Troubleshooting andDiagnostics4.1 Frequently Asked QuestionQuestion: How can I connect six pairs of D

Seite 21 - (DB-25 Connectors)

Chapter 4 - Troubleshooting and Diagnostics FLM-1 Installation & Operation Manual4-2 Fault Isolation and Troubleshooting 09/01/01 4:29 PMLocal Loo

Seite 22

FLM-1 Installation & Operation Manual Chapter 4 - Troubleshooting and Diagnostics09/01/01 4:29 PM Fault Isolation and Troubleshooting 4-3Table 4-

Seite 23

Safety WarningsThe exclamation point within a triangle is intended to warn the operator orservice personnel of operation and maintenance factors relat

Seite 24

Chapter 4 - Troubleshooting and Diagnostics FLM-1 Installation & Operation Manual4-4 Fault Isolation and Troubleshooting 09/01/01 4:29 PM

Seite 25 - Operating Instructions

09/01/01 4:29 PM A-1Appendix APin Assignment forSubchannels with DB-25ConnectorsTable A-1 Pin Assignment for Subchannels with DB-25 ConnectorsV.24 RS-

Seite 26 - 3.3 Operating Instructions

Appendix A - Pin Assignment for Subchannels with DB-25 Connectors FLM-1 Installation & Operation ManualA-2 09/01/01 4:29 PM

Seite 27 - Troubleshooting and

B-1Appendix BPinout for RJ-45ConnectorsThe pinouts of the RJ-45 connectors for the FLM-1 line (main channel) andsubchannels are given in Tables B-1 an

Seite 28 - Loopback

Appendix B - Pinout for RJ-45 Connectors FLM-1 Installation & Operation ManualB-2

Seite 29 - Symptom Action

Declaration of ConformityManufacturer’s Name: RAD Data Communications Ltd.Manufacturer’s Address: 24 Raoul Wallenberg St.Tel Aviv 69719Israeldeclares

Seite 30

FLM-1 Installation and Operation Manual iContentsCHAPTER 1 INTRODUCTION1.1 Overview ...

Seite 31 - Connectors

Contentsii FLM-1 Installation and Operation ManualCHAPTER 4 TROUBLESHOOTING AND DIAGNOSTICS4.1 Frequently Asked Question ...

Seite 32 - A-2 09/01/01 4:29 PM

FLM-1 Installation and Operation Manual iiiList of Figures Figure 1-1 Typical Point-to-Point Application...

Seite 33 - Pinout for RJ-45

List of Tablesiv FLM-1 Installation and Operation Manual

Seite 34

16/01/01 11:12 AM Overview 1-1Chapter 1Introduction1.1 OverviewGeneralFLM-1 is a full duplex time division asynchronous multiplexer enabling upto tw

Kommentare zu diesen Handbüchern

Keine Kommentare