120 Rockwell Automation Publication 750-TD001H-EN-P - June 2013
PowerFlex 750-Series AC Drives
Specifications - Communication Options and Accessories (continued)
20-XCOMM-DC-BASE 20-XCOMM-IO-OPT1 20-XCOMM-AC-PS1
Network
Protocol:
Data Rate:
Dependent on installed adapter
Dependent on installed adapter
––
Drive
Protocol:
Data Rates:
DPI
125/500 Kbps
––
Number of Inputs: 6 (single common)
Input Voltage Type: 24 VDC source load
Maximum Input Voltage: 27V DC
Rated Input Voltage: 100…240V AC
Operating Input Voltage: 90…264V AC
AC Input Frequency: 47…63 Hz
Maximum Input Current: 8 mA (each input)
Guaranteed ON-State Voltage: 10…27V DC (3 mA minimum)
Guaranteed OFF-State Voltage: 0…5V DC (2 mA maximum)
Reverse Polarity Protected: -30V DC
Input Response Time: 25 ms + network update time
(2)
(2) The I/O board is NOT designed for fast I/O response times. Do NOT use with input devices that will transition (OFF-ON-OFF) faster than the response time. Potential input devices include auxiliary contact
inputs from relays or overloads, pushbuttons, etc.
Number of Outputs: 2 relay outputs (individually isolated) 1 - Form C
contacts 1 - Form A (NO) contact
Maximum Output Contact
Voltage:
27V DC/125V AC
Maximum Output Contact
Current:
–2 A
Output Voltage: 24V DC
Output Current: 830 mA
Expected Contact Life: 1,000,000 cycles resistive at < 0.5 A
500,000 cycles inductive at < 0.5 A
500,000 cycles resistive at 1 A
300,000 cycles inductive at 1 A
300,000 cycles resistive at 2 A
150,000 cycles inductive at 2 A
Output Response Time: 25 ms + network update time
(3)
(3) The I/O board is NOT designed for fast I/O response times. Do NOT use with output devices that need to transition (OFF-ON-OFF) faster than the response time. Potential output devices include pilot lights
or a contact closure reset to another hardware device.
Consumption
Module:
Network:
60 mA at 12V DC supplied from drive via DPI cable
Ethernet: None
ControlNet: None
DeviceNet: 60 mA at 24V DC
––
DC Power Supply Requirement 20-COMM-C: 105 mA at 24V DC
(1)
20-COMM-D: 60 mA at 24V DC
(1)
20-COMM-E: 140 mA at 24V DC
(1)
20-COMM-Q: 135 mA at 24V DC
(1)
20-COMM-M: 140 mA at 24V DC
(1)
(1) Since the Comms Kit is powered by a nominal 24 VDC, the current consumption listed in this table differs from the value shown on the label of the communication adapter, which is based on the adapter
being powered by 5 VDC from the drive.
––
Dimensions (H x W x D): 108* x 108 x 75 mm
(4.25 x 4.25 x 2.95 in.)
with I/O terminal block attached
––
Weight: 340 g (12 oz)
Certifications
UL
c-UL
CE
C-Tick
UL508C
CAN/CSA C22.2 No. 14
––