RAD Data comm LRS-24 Spezifikationen Seite 65

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 64
Installation and Operation Manual Appendix C Command List
ASM-40CD Ver. 1.0 Modem Setup C-3
MODEM SETUP
MODEM NAME : ASM 40CD (m)
DEFINE MODEM PORT NUMBER : 1
MODEM STATUS : MASTER PERMANENT
SELECT MODEM : MODEM 1 LOCAL
SYNC/ASYNC : N/A CHARACTER LENGTH : N/A
No. STOP BIT : N/A DATA RATE : 2048k
PARITY : N/A CD SENSE : N/A
CLOCK SOURCE LOC/REM : L(INT) R(RCV) EXT SOURCE : N/A PORT: N/A
INTERFACE : N/A RTS/CTS DELAY(0:255) : N/A
RTS TO DCD : N/A DTR TO DSR : N/A
OUTPUT LEVEL : N/A INPUT LEVEL : N/A
OUTPUT IMPEDANCE : N/A ohm INPUT IMPEDANCE : 120 ohm
CARRIER CONTROL : ON ERROR CORRECTION : N/A
RATE ADAPTION METHOD : N/A AIS : N/A
LINE CODING : HDB83 PHANTOM : OFF
T1 LINE LENGTH : N/A
BRIDGING : N/A ETHERNET MODE : N/A
MASK SIGNAL STATUS : DATA:NO RTS:NO TD:NO RD:NO
DCD:NO TEST:NO ERR:NO LOS:NO
Figure C-2. Modem Setup Screen
Bolded rows in
Figure C-2
indicate parameters applicable to ASM-40CD and
standalone modems. Additional, non-bolded parameters listed on a screen apply
to other modems installed in the LRS-24 hub.
Table C-2
explains the transmission parameters and options for ASM-40CD that
can be viewed and set using the Modem Setup screen. The Write fields can be
changed only if the Master configuration mode is indicated in the Modem Status
field.
Table C-2. Modem Setup Screen
Parameter Type Function Options Option Indicates
MODEM NAME Read Identifying the modem
type whose status is being
viewed or modified
ASM-40CD(m) Master ASM-40CD
SELECT MODEM Write Selecting one of two
modems whose operational
parameters are set using
this screen.
Modem 1 Local
Modem 2 Local
Operational parameters will be set
for the modem installed in the LRS-
24 hub
DATA RATE Write Setting data rate
transmitted between
modems
32, 64, 128, 192, 256, 384, 512,
768, 1024, 1536, 1544, 1920, or
2048 kbps
CLOCK SOURCE
LOCAL/REMOTE
Write Timing mode
Note:
Clock mode of both
local and remote units
must be configured
manually.
L(INT), R(RCV) Crystal of the local modem is the
clock source; remote modem is
synchronized to the clock extracted
from the receive signal