Chapter 1 Introduction Installation and Operation Manual
1-2 Overview ASM-40CD Ver. 1.0
Figure 1-2
shows a power feeding application, where ASM-40CD/P card receives
the feed voltage from a standalone power supply unit, LRS-PS-FEED, connected
to the LRS-24 modem rack and supplies the voltage to two RPT repeaters.
Central Site
Remote Site
LRS-24
ASM-40CD/P
Router
Router
ASM-40
ASM-40
RPT RPT
RPT RPT
Remote Power Feeding
Up to 4 km (2.4 miles)
LRS-PS-FEED
PCM
Figure 1-2. ASM-40CD/P Providing Remote Power Feed to Repeaters
Features
ASM-40CD offers selectable data rates from 32 kbps to 2048 kbps, and
automatic rate detection in external mode for tail-end applications.
DTE Interface
The ASM-40CD DTE interface is provided using the appropriate interface module:
• LRSI-F-5 for V.24/RS-232 (64 kbps), V.35, X.21, RS-530, and V.36 interfaces
(via adapter cables)
• LRSI-F-14 for IR-ETH (Ethernet bridge) or IR-ETH/QN (Ethernet/Fast Ethernet
bridge with VLAN support).
Management
Full management of the local unit from an ASCII terminal or by a Unix HPOV
application via the LRS-24 Ethernet segment is available. Simultaneous control
and monitoring of local units is available without any impact or interference to
the user data being transmitted.
Diagnostics
ASM-40CD has real-time alarms indicating status of local and remote units.
ASM-40CD has V.54 diagnostic capabilities (local analog, remote digital and local
digital loopbacks) and an internal pseudo-random test pattern (511-bit) in
accordance with the ITU V.52 standard.