Chapter 4 Performance Monitoring RADview-EMS ASMi-52 User’s Manual
4-8 SHDSL Link Port Level – Statistics Menu
Table 4-4. 15 min Interval Data Parameters (Cont.)
Parameter Possible Values/Remarks
SES The number of severely errored seconds
0…899
CRC Anomalies The CRC (Cyclical Redundancy Checking) anomalies that have occurred since the
beginning of the last 24-hour period
LOSWS The number of sync word seconds that have been lost
0…899
UAS The number of unavailable seconds
0…899
[Close] Click <Close> to close the 15 min Interval Data dialog box
Viewing One-Day Interval Data for the SHDSL Link Port
The Line > One Day Interval Data command enables you to view SHDSL Link
port data at one-day intervals.
To view port data at one-day intervals:
At the SHDSL Link port level, select Statistics > Line > One Day Interval
Data…