User's Manual Chapter 6 Performance Management
RADview-SC/TDMoIP IPmux-11 Viewing Port Intervals Statistics 6-9
Figure 6-6. Port Intervals Statistics
Table 6-5. Port Intervals Statistics Parameters – E1/T1
Parameter Remarks
Slot 1
Port CH1
Type E1, T1
Number of
Intervals
Number of intervals sampled
Inv No. Interval Number
From (hh:mm) Starting time of the interval
To (hh:mm) Ending time of the interval
ES Errored Seconds
A second containing one or more of the following events: CRC error, SEF (OOF), or AIS.
Note:
An OOF defect is the occurrence of a framing bits error.
If SES also occurs at the same time, ES will stop after 10 seconds.