Chapter 4 Configuring Typical Applications User's Manual
4-10 Creating Circuits RADview-SC/TDMoIP IPmux-11
Creating a Circuit
To create a circuit between IPmux-11 (172.12.157.10) and IPmux-14
(172.17.157.14):
1. On the Services Map, select the source for the circuit. In this example it is the
IPmux-14 (172.17.157.10).
2. While holding down the CTRL key, right click the mouse and drag a line
between the source IPmux-11 (172.12.157.10) and destination IPmux-14
(172.17.157.14).
The Manual Circuit Configuration dialog box appears.
Figure 4-9. Manual Circuit Dialog Box – General Parameters Tab
3. Click on the General tab (
Figure 4-9) and configure the following parameters:
Connection Type = E1
Connection Bandwidth = 10xTs