Seitenansicht 65
Chapter 3 Configuration Management User’s Manual
3-36 Setting the Operational Parameters RV-EMS/NGN LA-210
Figure
3-27. Bridge Port List
4. Choose the desired port, add it to the bridge and configure the associated
parameters as detailed in
Table
3-16
.
Figure
3-28. Bridge Port Screen
Table
3-16. Bridge Port Parameters
Parameter Possible Values / Remarks
Port The selected port
Administrative Status
Specifies if this port is part of the bridge or not.
Up (part of the bridge)
Down (not part of the bridge)
Default: Up
Ingress Filtering
When Enabled, the device discards incoming frames for VLANs which do not
include this port in its member set. When Disabled, the port accepts all incoming
Seitenansicht 65