Appendix C SNMP Management FCD-IPM Installation and Operation Manual
C-6 SNMP Traps
2. Choose Setup Host Parameters.
3. Choose SNMP Manager Table.
4. Add the NMS station IP address to the manager list.
5. Choose YES under MASK parameter to open the trap mask.
C.3 SNMP Traps
The SNMP agent of the FCD-IPM supports the standard MIB-II traps. In addition,
each FCD-IPM alarm is sent as a specific trap to the management station.
Supported Traps
The supported traps are:
Cold Start
Link Down
Link Up
Authentication Failure
Dsx1LineStatusChange.
This trap provides alarm indications for the following alarms:
1 dsx1NoAlarm No alarm present
2 dsx1RcvFarEndLOF Far end LOF (Yellow alarm)
16 dsx1XmtAIS Near end sending AIS
32 dsx1LossOfFrame Near end LOF (Red alarm)
64 dsx1LossOfSignal Near end loss of signal
128 dsx1LoopbackState Near end is looped
512 dsx1RcvFarEndLOMF Far end sending TS16 LOMF
1024 dsx1XmtFarEndLOMF Near end sending TS16 LOMF.