FOM-40 Installation and Operation Manual Appendix C IR-G.703/CO Interface Module
Selecting the IR-G.703/CO Timing C-3
INT/RCV Timing
The INT/RCV clock is used in applications that recover the clock signal from the
modem link. This mode is used when the attached equipment has a G.703
codirectional interface but cannot produce clock signals. The module has an 8-bit
FIFO buffer to compensate for the phase delay introduced by the G.703 device.
Figure C-4 illustrates the buffer connection and the required application setup.
If the FOM-40 modem is set to the internal or receive timing, configure the
IR-G.703/CO module to the INT/RCV clock.
TX
RX
RX Data
TX Data
TX
RX
INT or RCV
Clock Mode
EXT, INT or RCV
Clock Mode
(Depending on the
attached network)
Modem
Equipment
with G.703
Interface
LINK
Side
G.703
Side
DTE
Side
INT/RCV Clock Mode
Modem B
Clock In
Clock
Out
IR-G.703 Module
Data
Clock
Recovery
FIFO
Clock
Recovery
Data
CLK
FIFO
Figure C-4. IR-G.703/CO INT/RCV Timing