ultiservice Access Nodes
DXC-100
• DXC-100 can also aggregate
Ethernet traffic (for example, ISP or
corporate traffic) from several
remote sites via different trunks into
one stream, by using the
channelized router module.
BASIC UNITS
• The basic DXC-100 chassis is
6U-high (10.5 inches), and is NEBS
Level 3 certified. The chassis
includes eleven I/O slots for plug-in
interface module sets. Each module
set consists of a front main module
and a rear interface module. The
power supply and system manager
modules are not provided with the
chassis and must be ordered
separately. Optional redundancy for
the system manager and power
supply modules is available.
• The chassis can be mounted in a
19-inch wide rack. Optional
23-inch flush and 23-inch center
mount brackets are also available.
• Up to 8 DXC-100 units can be
stacked in a star topology. Nest 1 is
a master unit, while nests 2 to 8 are
slave units. The master unit has a
different main system manager
module (DXNM) and an additional
expansion module (DXCC). The
slave units have the same main
system manager module (DSMC.2),
and an additional stack controller
module (DXLC).
• When a standalone unit is
expanded into a stack, all of its
modules are used and no resources
are wasted.
SYSTEM MANAGER MODULES
• A standalone DXC-100 requires one
or two DSMC.2 half-height main
modules and one DSMC.2 full-height
interface module.
• Nest 1 in a DXC-100 stack requires
one or two (recommended)
half-height DXNM main modules with
one full height DSMC.2 interface
module and one or two
(recommended) full-height DXCC
main and interface modules.
• Nests 2 to 8 require one or two
DSMC.2 half-height main modules
and one or two (recommended)
full-height DXLC main modules. The
DSMC.2 interface module is optional
and intended for use only when the
DXC-100PSX is used. For each of the
DXLC modules, a D8E1T1 interface
module can be installed at the rear of
the chassis, to provide additional 8
E1/T1 ports each.
DSMC.2 Main Module
• A standalone unit, as well as Nests 2
to 8 of stacked units, use the
half-height DMSC.2 system
management main module, placed
in a specially designed slot. Two
such slots are available for optional
system redundancy. The DSMC.2
module can generate a Stratum 3
clock source.
DSMC.2 INTERFACE MODULE
• A single full-height interface module
supports up to two DSMC.2 or
DXNM main modules and is
rear-mounted into a dedicated slot.
The interface module contains
management 10/100BaseT Ethernet
and supervision terminal ports,
phone line (connected to internal
modem) and critical/major/minor
alarm dry contacts.
DXNM Main Module
• Nest 1 of the stacked units uses the
half height DXMN system
management main module instead
of the DSMC.2 module. The DXMN
module is placed in a specially
designed slot. Two such slots are
available for optional system
redundancy. The DXNM module
provides a Stratum 3 or external
clock to all units. The interface
module for Nest 1 is the same as for
a standalone unit (DSMC.2).
DXCC and DXLC Main and Interface
Modules
• Matrix expansion modules are the
DXCC module for Nest 1 and the
DXLC module for Nests 2 to 8. The
DXCC and DXLC modules are
connected via an external cable.
The DXCC module creates a
transparent switch fabric for a
non-blocking 3/1/0 cross-connect
between any ports of the stacked
units.
Figure 1. Multiservice Access Platform
APPLICATIONS
Kommentare zu diesen Handbüchern