Installation and Operation Manual Chapter 5 Monitoring and Diagnostics
Optimux-108 Ver. 6.1 Performing Diagnostic Tests 5-19
Local Optimux-108
Figure
5-18 V.35 Local Loopback
³ To run a loopback on a V.35 user port:
1. In the Diagnostics Menu (
Figure
5-12
), set Device Number to Local.
2. Choose V.35 Loop Type.
The loopback test begins running immediately after the loopback is set.
Clearing Loopbacks
³ To clear a specific loopback:
Select No loop in the specific loopback screen.
The loopback test is disconnected immediately after this option is
selected.
³ To clear all loopbacks:
1. From the Diagnostics menu, select Clear all channel’s loops.
All the loopback tests are disconnected immediately after this option is
selected.