IPmux-8/16 User’s Manual Chapter 3 Configuration Management
Configuring IPmux-8/16 Ports at the Physical Layer 3-25
Configuring E3/T3 Parameters
To display or configure E3/T3 parameters:
1. Click an E3/T3 port.
2. Configuration > Parameters...
The E3/T3 Parameters dialog box appears.
Figure 3-19. E3/T3 Parameters Dialog Box
Table 3-12. E3/T3 Interface Parameters
Parameter Possible Values / Remarks
Slot 3, 4
Port CH1
Type E3, T3
Mask Port Indication Check-box: Checked = Mask, Unchecked = Unmasked
Transmit Clock Source Source of the transmit clock
Internal: Local clock source is used
External: Recovered from the other interface network and used for data
transmission on this interface (will not be supported in next phase)
Loopback: Transmit clock recovered from received data
Adaptive
: Adaptive clock regeneration