Release Note
Subject Description Status
QoS
MEP is not supported on flows
terminating on bridge ports
TRS 13655
After changing the “ethertype” value
for a port, the MEP enters into the
“fail” status and the Ethernet OAM&P
functionality stops working.
Workaround: Reconfigure the relevant
port and flows
TRS 13656
Clock Domain
When the SDH/SONET clock is used, all
the DS0 cross-connect services must
be locked to this clock.
Workaround: Use transparent E1/T1
over SDH/SONET for clock
transparency.
TRS 11739
Connecting/disconnecting the station
clock sometimes causes data errors in
services
TRS 13469
The following trap variables are
missing in the trap for
“clockDomainSystemSrcClockChange “
alarm:
2863.ifAlias
rad.csmSourceQL
rad.csmDomainLastSystemSrcClkS
witchReason
TRS 13475
Stopping to transmit SSM messages to
the Megaplex station port has no
effect on the station clock status: it
still displays the last quality value
TRS 13470
Transmitting an SSM message to the
Megaplex station port with “ST4”
quality results in displaying “SMC”
quality
TRS 13470